Energy absorbing steel post terminal to be used with W-beam safety barriers.  During head-on impacts, longitudinal forces releases the upper post to slide rearward and absorbs the impacted energy.  During side impacts, the upper and lower posts act together to redirect errant vehicles.
Features:
  • Breakaway steel post technology
  • easy transport and installation

Details:

Length: 12.35 m
Post Spacing: 1.333 m
European EN1317-3 Tested: 110 km/h (70 mph) with 900 kg (1984 lbs) and 1500 kg (3304 lbs)
Not tested for NCHRP 350

For Complete Specification: Energy Absorption Systems, Inc.